UPS management software and accessories function

發(fā)布時間: 2010/02/24 人氣 :11068

·UPS management software and accessories function

1, monitoring and alarm functions

When UPS monitoring software is running, the computer sends query commands to the UPS, monitoring UPS operating parameters, such as: input voltage, output voltage, current and frequency, UPS battery charge, discharge voltage, UPS output power and so on. A computer judges docking parameters received from UPS and determines that UPS is currently running the state, such as UPS mains interruption, UPS battery low potential, UPS failure, UPS overload of information, as well as the type and exact location of fault information, and, when necessary, UPS issued a instructions to intervene to remind the maintenance personnel. When the UPS software and accessories UPS system failure is detected, it can inform the system administrator by e-mail, pager, pop-up messages, SMS, etc. in real time to resolve the problem as quickly as possible, shorten recovery time.

2, data protection

When the UPS system fail or battery power will be running out, UPS software and accessories execute pre-configured data protection features, and close the security application databases and operating systems, thus ensuring data and system integrity and recoverability, this is an important too to shorten recovery time. In addition, customers can customize according to actual needs of their specific program of automatic shut-off function.

3, diagnostic and maintenance functions

Some UPS monitoring software and accessories provide remote monitoring capabilities, through the UPS monitoring software and accessories can be remotely check the status of UPS and check for early warning information, UPS battery calibration experiment, These preventive functions can take appropriate measure before they occur system failure ,which is a powerful tool to improve system availability.

4, UPS and its software / accessories to provide regular UPS self-test function

The main components to check UPS include inverter, charger, batteries and control unit, preventing potential dangers. This is done through the initiative of software and accessories which is also a powerful tool to prevent the failure of UPS.

5, the network communication function

Network Systems UPS monitoring software enables two-way communication between the UPS and computer network. UPS equipped with communications adapter is treated as a separate network address of the node, an administrator anywhere in the network management computer network like the same right UPS carry out real-time remote monitoring, access to UPS operating parameters (for example: input voltage, output voltage, current and frequency, UPS battery charge, discharge and voltage values of the display, UPS output power and the fault and alarm information). In addition, users can also be a computer network terminal on the output of the implementation of regular UPS automatic start, automatic shutdown mode to ensure that the user's software and data safe and secure.

6, maximum run-time control of UPS

Products in this respect is few, but there has been a very good program, such as Master Switch intelligent power distribution accessories, it shut down a large consumption of non-core equipment through remote operation such as printers, while the core equipment is to ensure such as servers, routers, etc. to achieve the longest run time. Such an approach can not only improve system availability, but also can greatly reduce system power consumption, lower system operating costs.

7, operation access control

Software and accessories provide timer switch machines and different levels of operating authority for customer with high security requirements, to prevent non-authorized personnel caused by the illegal operation fault. General users, system administrators and information administrator have different access to management and operation rights.

?